Bookmark and Share

Experimental characterization of interstitial pore pressure in concrete under high confinement

Show simple item record

dc.contributor.author Accary, Abdallah
dc.contributor.author Daudeville, Laurent
dc.contributor.author Malecot, Yann
dc.date.accessioned 2018-11-27T08:09:21Z
dc.date.available 2018-11-27T08:09:21Z
dc.date.issued 2017
dc.identifier.citation Accary, Abdallah ; Daudeville, Laurent ; Malecot, Yann. Experimental characterization of interstitial pore pressure in concrete under high confinement. 23ème Congrès Français de Mécanique, 28 août - 1er septembre 2017, Lille, France (FR), AFM
dc.identifier.issn 2491-715X
dc.identifier.uri http://hdl.handle.net/2042/69026
dc.description.abstract Le but de cette étude est de mesurer la pression interstitielle du béton sous haut niveau de confinement. Lorsque les structures de béton sont soumises à un chargement de type impact ou explosion, le matériau subit de très fortes contraintes triaxiales qui sont fortement influencées par le taux de saturation. Afin de mesurer la pression interstitielle d’eau à l’intérieur du béton sous fort chargement triaxial, un nouveau dispositif expérimental a été développé. Des éprouvettes de 14 cm de longueur et 7 cm de diamètre sont testées à l’aide de la presse GIGA. Dans le nouveau concept, la longueur de l’échantillon est réduite à 8 cm et une enclume de mesure de la pression interstitielle de longueur 6 cm a est incorporée. Des micro-trous sont percés sur sa face supérieure de sorte que la pression de l’eau libre dans l’échantillon puisse ainsi être transmise dans la cavité durant l’essai. Un capteur cylindrique équipé d’une jauge est placé dans la cavité permet de mesurer cette pression. Les résultats préliminaires d’un essai hydrostatique effectué sur un béton saturé indiquent que la pression interstitielle a augmenté jusqu’à 200 MPa pour 300 MPa de confinement. fr
dc.description.abstract This study focuses on measuring the pore pressure of concrete under high confinement. When concrete structures are subjected to an impact loading, material exhibits high triaxial compressive stresses which are highly influenced by the saturation ratio. In order to measure the interstitial water pore pressure inside the concrete under mechanical loading, a new experimental device was developed. Usually, specimens of 14cm in length and 7cm in diameter are tested using the GIGA press. In the new concept, the specimen length is reduced to 8cm and a pore pressure measurement cell of 6 cm in length is incorporated. The cell has micro-holes on its upper face, so that, when the specimen is loaded water pressure is transmitted from concrete to the cell where a cylindrical sensor equipped with a gage is placed. Preliminary results indicate that concrete pore pressure increases up to 200 MPa during an hydrostatic test at 300 MPa of confinement. en
dc.language.iso en
dc.publisher AFM, Association Française de Mécanique
dc.relation.ispartof S27 - Couplage durabilité - Comportement mécanique dans les structures de génie civil
dc.relation.ispartofseries Congrès français de mécanique
dc.rights Accès libre - Licence d'utilisation : http://irevues.inist.fr/utilisation
dc.source 23ème Congrès Français de Mécanique, 28 août - 1er septembre 2017, Lille, France (FR)
dc.subject concrete en
dc.subject confinement pressure en
dc.subject pore pressure en
dc.subject experiment en
dc.title Experimental characterization of interstitial pore pressure in concrete under high confinement en
dc.type conference meeting-part
dc.contributor.affiliation Univ. Grenoble Alpes, CNRS, Grenoble INP, 3SR, F-38000 Grenoble


Files in this item

PDF 133783.pdf 1.070Mb

This item appears in the following Collection(s)

Show simple item record

  • Président comité d'organisation : Thomas Rougelot
  • Président du conseil scientifique : Jianfu Shao
  • Co-Présidents du conseil scientifique : Gilmar Mompean et Eric Markiewicz
  • Editeur : Association Française de Mécanique
  • ISSN : 2491-715X (en ligne)
  • Contact : cfm2017